QinetiQ currently produces four sizes of hollow cathode, each with different operating current ranges:
- T5 and T6 gridded ion thrusters (0.5 - 3.6A)
- ROS-2000 Hall Effect Thruster (or 'HET' developed by Astrium under contract to ESA) (3 - 20A)
- 5.0 kW HET (2 - 10A)
- Miniaturised HET (0.5 - 5A)
The T6 design has been extensively tested to 35A, and an earlier version was used successfully in the UK-25 300mN ion thruster, where currents of 30A were routinely employed. QinetiQ has also developed a device rated for continuous operation at 30A with extended operation at up to 50A.
|
|
 |
|
|
|
|
 |
|
|
7mm Diameter cathodes can be configured for many applications. |
|
 |
|
|
The 7 mm cathodes have been qualified for the ESA/Astrium ROS-2000 Hall effect product and are undergoing qualification for the QinetiQ T6 and further European Hall effect systems. This has included the following:
- Environmental qualification to 43 grms.
- 2 x cathodes successfully completed 5500 rapid on/off cycles for the ROS-2000 thruster.
- 1 x cathode successfully completed 18,000 rapid on/off heater cycles.
- 1x cathode successfully completed 5500 rapid on/off heater cycles followed by 4200 hours of operation at 18 A.
- Life testing of two cathodes to be completed as part of the Astrium EADS ROS-2000 lifetest.
- 7 mm cathodes successfully passed accelerated contamination tests. This used artificially high levels of gas impurities to demonstrate compliance with required total in-service impurity levels.
|
|
 |
|
|
7mm Diameter Hollow Cathodes technical data:
|
|
 |
|
|
Mass: 120 gm DC Ampere hours: > 15,000 hours @ 15 A NC Ampere hours: > 15,000 hours @ 3 A DC and NC cycle life: > 5,500. Emitter technology: BaO based In-orbit life: No degrading effects from space exposure. Ground storage: No shelf life or need to flush with shield gas (e.g. dry nitrogen). Propellant quality: > 4.7 grade (see data on 3 mm cathode) Vibration / shock: 43 g rms, 1000 g.
|
|
 |
|
|
|
>
Hollow Cathode Technology Factsheet
[PDF]
|
|
 |
|
|